Table 89: MX480 Router Common Component Power Requirements
Power Requirement (Watts)Component
40 WBase system
110 WNormal-capacity cooling system
160 WHigh-capacity cooling system
NOTE: The power for the cooling system comes from a different tap on the
power supply, reserved forthe coolingsystem only. Thecooling systempower
requirement does not need to be deducted from the output power budget
of the power supply.
Table 90: FRU Power Requirements
Maximum Power RequirementPart NumberComponent
Switch Control Boards (SCBs)
150 WSCB-MX960
(applies to
MX240, MX480,
and MX960)
SCB
160 W at 55° C
130 W at 40° C
120 W at 25° C
SCBE-MX
(applies to
MX240, MX480,
and MX960)
SCBE
185 W at 55° C
160 W at 40° C
155 W at 25° C
SCBE2-MX
(applies to
MX240, MX480,
and MX960)
SCBE2
Routing Engines
90 WRE-S-1300-2048
RE-S-1800X2-8G
RE-S-1800X4-8G
RE-S-1800X2-16G
RE-S-1800X4-16G
RE-S-1800X4-32G
RE-S-2000-4096
RE-S-X6-64G
Routing
Engines
159Copyright © 2017, Juniper Networks, Inc.
Chapter 13: DC Power Requirements, Specifications, and Guidelines