The green OK/FAIL LED should light steadily a few minutes after the SCB is installed.
If the OK/FAIL LED is red, remove and install the SCB again. If the OK/FAIL LED still
lights steadily, the SCB is not functioning properly. Contact your customer support
representative.
7. Check the status of the SCB using the show chassis environment cb command:
user@host> show chassis environment cb
CB 0 status:
State Online Master
Temperature 25 degrees C / 77 degrees F
Power 1
1.2 V 1198 mV
1.5 V 1508 mV
1.8 V 1830 mV
2.5 V 5059 mV
3.3 V 6593 mV
5.0 V 5111 mV
12.0 V 12181 mV
1.25 V 1250 mV
3.3 V SM3 6587 mV
5 V RE 5078 mV
12 V RE 12026 mV
Power 2
11.3 V bias PEM 11253 mV
4.6 V bias MidPlane 4827 mV
11.3 V bias FPD 11408 mV
11.3 V bias POE 0 11446 mV
11.3 V bias POE 1 11408 mV
Bus Revision 6
FPGA Revision 0
CB 1 status:
State Online Standby
Temperature 26 degrees C / 78 degrees F
Power 1
1.2 V 1211 mV
1.5 V 1517 mV
1.8 V 1817 mV
2.5 V 2507 mV
3.3 V 3312 mV
5.0 V 5136 mV
12.0 V 12142 mV
1.25 V 1260 mV
3.3 V SM3 3306 mV
5 V RE 5085 mV
12 V RE 11968 mV
Power 2
11.3 V bias PEM 11369 mV
4.6 V bias MidPlane 4814 mV
11.3 V bias FPD 11427 mV
11.3 V bias POE 0 11350 mV
11.3 V bias POE 1 11330 mV
Bus Revision 39