1 Online 43 5 0 1024 16 57
2 Online 43 11 0 1024 16 57
3 Empty
4 Empty
5 Online 42 6 0 1024 16 57
For more detailed output, add the detail option. The following example does not specify
a slot number, which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:33 PDT
Uptime: 1 hour, 33 minutes, 52 seconds
Max Power Consumption 368 Watts
Slot 1 information:
State Online
Temperature 43 degrees C / 109 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:38 PDT
Uptime: 1 hour, 33 minutes, 47 seconds
Max Power Consumption 249 Watts
Slot 2 information:
State Online
Temperature 43 degrees C / 109 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:40 PDT
Uptime: 1 hour, 33 minutes, 45 seconds
Max Power Consumption 335 Watts
Slot 5 information:
State Online
Temperature 42 degrees C / 107 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:42 PDT
Uptime: 1 hour, 33 minutes, 43 seconds
Max Power Consumption 333 Watts
• Issue the CLI show chassis fpc pic-status command. The DPC slots are numbered 0
through 5, bottom to top:
user@host> show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R
PIC 0 Online 1x 10GE(LAN/WAN)
PIC 1 Online 1x 10GE(LAN/WAN)
PIC 2 Online 1x 10GE(LAN/WAN)
PIC 3 Online 1x 10GE(LAN/WAN)
Slot 1 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
421Copyright © 2017, Juniper Networks, Inc.
Chapter 29: Maintaining Components