3.3 Main Circuit Wiring
62 SIEPCYEUOQ2V01A Q2V Technical Manual
Model Terminal
Recommended
Gauge
mm
2
Applicable Gauge
mm
2
Wire
Stripping
Length
*1
mm
Terminal Screw
Tightening Torque
Nm (inlb)
Size Shape
2042
R/L1, S/L2, T/L3 14 3.5 - 14 10 M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3 14 3.5 - 14 10 M4
1.5 - 1.7
(13.5 - 15)
-, +1, +2 22 5.5 - 30 18 M5
22 mm
2
2.3 - 2.5
(19.8 - 22)
30 mm
2
4.1 - 4.5
(36 - 40)
B1, B2 5.5 3.5 - 8 10 M4
1.5 - 1.7
(13.5 - 15)
8
*2
5.5 - 14 - M5
2.0 - 2.5
(17.7 - 22.1)
2056
R/L1, S/L2, T/L3 22 5.5 - 30 18 M5
22 mm
2
2.3 - 2.5
(19.8 - 22)
30 mm
2
4.1 - 4.5
(36 - 40)
U/T1, V/T2, W/T3 14 5.5 - 22 18 M5
2.3 - 2.5
(19.8 - 22)
-, +1, +2 30 8 - 30 18 M5
22 mm
2
2.3 - 2.5
(19.8 - 22)
30 mm
2
4.1 - 4.5
(36 - 40)
B1, B2 14 2 - 14 10 M4
1.5 - 1.7
(13.5 - 15)
8
*2
8 - 22 - M6
5.4 - 6.0
(47.8 - 53.1)
2070
R/L1, S/L2, T/L3 30 8 - 38 20 M6
5 - 5.5
(45 - 49)
U/T1, V/T2, W/T3 22 5.5 - 30 20 M6
5 - 5.5
(45 - 49)
-, +1, +2 38 14 - 50 20 M6
5 - 5.5
(45 - 49)
B1, B2 14 5.5 - 14 10 M4
1.5 - 1.7
(13.5 - 15)
14 8 - 22 - M6
5.4 - 6.0
(47.8 - 53.1)
2082
R/L1, S/L2, T/L3 38 14 - 50 20 M6
5 - 5.5
(45 - 49)
U/T1, V/T2, W/T3 30 8 - 38 20 M6
5 - 5.5
(45 - 49)
-, +1, +2 50 22 - 60 20 M6
5 - 5.5
(45 - 49)
B1, B2 14 5.5 - 14 10 M4
1.5 - 1.7
(13.5 - 15)
14 8 - 22 - M6
5.4 - 6.0
(47.8 - 53.1)
*1 Remove insulation from the ends of wires to expose the length of wire shown.
*2 If you turn on the built-in EMC filter, the leakage current of the drive will be more than 3.5 mA. Use these closed-loop crimp
terminals or equivalent to connect a protective ground wire that has a minimum cross-sectional area of 10 mm
2
(copper wire).
8-4NS from JST Mfg. Co., Ltd.
R8-4S from NICHIFU Co.,Ltd.

Table of Contents

Related product manuals