9 - 79
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-5 Modbus Communication Register Number List
9
9-5-6 Group C Register List
386Eh 386Dh
Window comparator for [Ai3]
higher level
CE-46 R/W -100 to 100 1(%)
386Fh 386Eh
Window comparator for [Ai3]
lower level
CE-47 R/W -100 to 100 1(%)
3870h 386Fh
Window comparator for [Ai3]
hysteresis width
CE-48 R/W 0 to 10 1(%)
3872h 3871h
Operation level at [Ai1] dis-
connection
CE-50 R/W 0 to 100 1(%)
3873h 3872h
Operation level selection at
[Ai1] disconnection
CE-51 R/W
00: Disabled
01: Enabled: out of range
02: Enabled: within the range
-
3874h 3873h
Operation level at [Ai2] dis-
connection
CE-52 R/W 0 to 100 1(%)
3875h 3874h
Operation level selection at
[Ai2] disconnection
CE-53 R/W
00: Disabled
01: Enabled: out of range
02: Enabled: within the range
-
3876h 3875h
Operation level at [Ai3] dis-
connection
CE-54 R/W -100 to 100 1(%)
3877h 3876h
Operation level selection at
[Ai3] disconnection
CE-55 R/W
00: Disabled
01: Enabled: out of range
02: Enabled: within the range
-
38A5h 38A4h
RS485 communication baud
rate selection
CF-01 R/W
03:2400bps
04:4800bps
05:9600bps
06:19.2kbps
07:38.4kbps
08:57.6kbps
09:76.8kbps
10:115.2kbps
-
38A6h 38A5h
RS485 communication Node
allocation
CF-02 R/W 1 to 247 1
38A7h 38A6h
RS485 communication parity
selection
CF-03 R/W
00: Without parity
01: Even number parity
02: Odd number parity
-
38A8h 38A7h
RS485 communication
stop-bit selection
CF-04 R/W
01: 1bit
02: 2bit
-
38A9h 38A8h
RS485 communication error
selection
CF-05 R/W
00: Error
01: Trip after deceleration stop
02: Ignore
03: Free run
04: (Deceleration stop)
-
38Aah 38A9h
RS485 communication time-
out setting
CF-06 R/W
0 to 10000
(0:Disable Communication Time-
out)
0.01(s)
38Abh 38AAh
RS485 communication wait
time setting
CF-07 R/W 0 to 1000 1(ms)
38Ach 38ABh
RS485 communication mode
selection
CF-08 R/W
01: Modbus-RTU
02: EzCOM
03: EzCOM management
-
38AFh 38AEh Resister data selection CF-11 R/W
00: A,V
01: %
-
38B8h 38B7h EzCOM Start node No. CF-20 R/W 01 to 08 1
38B9h 38B8h EzCOM End node No. CF-21 R/W 01 to 08 1
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution