Appendices C Table of Parameters
C - 48
High-function General-purpose Inverter RX2 Series User’s Manual
CC-54 ○
Logical calculation symbol selection
of LOG5
00 (AND)/01 (OR)/02 (XOR) 00
CC-55 ○
Logical calculation target 1 selection
of LOG6
See <List of output terminal functions> on page C-49
062: LOG1 to 068: LOG7 cannnot be selected.
000
CC-56 ○
Logical calculation target 2 selection
of LOG6
See <List of output terminal functions> on page C-49
062: LOG1 to 068: LOG7 cannnot be selected.
000
CC-57 ○
Logical calculation symbol selection
of LOG6
00 (AND)/01 (OR)/02 (XOR) 00
CC-58 ○
Logical calculation target 1 selection
of LOG7
See <List of output terminal functions> on page C-49
062: LOG1 to 068: LOG7 cannnot be selected.
000
CC-59 ○
Logical calculation target 2 selection
of LOG7
See <List of output terminal functions> on page C-49
062: LOG1 to 068: LOG7 cannnot be selected.
000
CC-60 ○
Logical calculation symbol selection
of LOG7
00 (AND)/01 (OR)/02 (XOR) 00
Code
Codes that
can be
changed
during
operation
Name Data range
Initial
value
Note