Remote control commands
R&S
®
SMA100B
659User Manual 1178.3834.02 ─ 09
Parameters:
<Shape> SINE | SQUare | PULSe | TRIangle | TRAPeze
*RST: SINE
Example: See Example "Configuring the LF generator" on page 653.
Options: TRIangle|TRAPeze require R&S SMAB-K24
Manual operation: See "Shape" on page 114
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:DCYCle <DCycle>
Sets the duty cycle for the shape pulse.
Parameters:
<DCycle> float
Range: 1E-6 to 100
Increment: 1E-6
*RST: 50
Default unit: PCT
Example: See Example "Configuring the LF generator" on page 653.
Manual operation: See "Pulse Duty Cycle" on page 116
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:PERiod <Period>
Sets the period of the generated pulse. The period determines the repetition frequency
of the internal signal.
Parameters:
<Period> float
Range: 1E-6 to 100
Increment: 1E-8
*RST: 1E-3
Example: See Example "Configuring the LF generator" on page 653.
Manual operation: See "Period" on page 116
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:WIDTh <Width>
Sets the pulse width of the generated pulse.
Parameters:
<Width> float
Range: 1E-6 to 100
Increment: 1E-8
*RST: 5E-4
Example: See Example "Configuring the LF generator" on page 653.
Manual operation: See "Pulse Width" on page 116
SOURce subsystem