RF signal configuration
R&S
®
SMA100B
72User Manual 1178.3834.02 ─ 09
The "Frequency" tile indicates the reference frequency, current frequency offset
and multiplier values, and phase offset value.
In the "RF Frequency" dialog, you can configure:
RF frequency, incl. an offset or multiplication factor of a downstream instrument
The step size for varying the frequency with the rotary knob.
The remote commands required to define the settings are described in Chap-
ter 14.16.4, "SOURce:FREQuency subsystem", on page 642.
Settings
Frequency..................................................................................................................... 72
Main PLL Bandwidth..................................................................................................... 73
Offset.............................................................................................................................73
Multiplier........................................................................................................................73
User Variation................................................................................................................73
Variation Active............................................................................................... 73
Variation Step..................................................................................................73
Frequency
Sets the RF frequency.
This frequency is output at the RF connector. It does not consider an Offset or multipli-
cation factor (Multiplier).
See "RF frequency and level display with a downstream instrument" on page 66.
Note: Suppressed values in the status bar
For security concerns or certain operating modes, you can hide the frequency and
level display in the status bar.
The display has been disabled for security reasons.
See:
Annotation Frequency
Annotation Amplitude
The display is disabled when list mode is running, see Chapter 7, "List and sweep
mode", on page 171.
Remote command:
[:SOURce<hw>]:FREQuency[:CW|FIXed] on page 644
RF frequency settings

Table of Contents