Remote control commands
R&S
®
SMA100B
734User Manual 1178.3834.02 ─ 09
:SYSTem:NTP:STATe <UseNtpState>
Activates clock synchronization via NTP.
Parameters:
<UseNtpState> 1 | ON | 0 | OFF
*RST: n.a. (factory preset: 0)
Example:
SYSTem:NTP:STATe 1
Manual operation: See "Use Time from NTP Server" on page 767
:SYSTem:TIME
<Hour>, <Minute>, <Second>
Queries or sets the time for the instrument-internal clock.
This is a password-protected function. Unlock the protection level 1 to access it.
Parameters:
<Hour> integer
Range: 0 to 23
<Minute> integer
Range: 0 to 59
<Second> integer
Range: 0 to 59
Example:
SYSTem:TIME?
// 10,27,14
Manual operation: See "Time" on page 767
:SYSTem:TIME:ZONE <TimeZone>
Sets the timezone. You can query the list of the available timezones with :SYSTem:
TIME:ZONE:CATalog?.
Parameters:
<TimeZone> string
Manual operation: See "Timezone" on page 767
:SYSTem:TIME:ZONE:CATalog?
Querys the list of available timezones.
Return values:
<Catalog>
Usage: Query only
Manual operation: See "Timezone" on page 767