AQUASTORMâ„¢ OPTIONS GUIDE
Manual Part # 3-9317-600-00-0
ELECTROVERT | Aquastorm

Table of Contents

Questions and Answers

  • D
    David DixonAug 3, 2025
    Why is the mV output erratic on my Speedline Technologies ELECTROVERT Aquastorm Industrial Equipment?
    • L
      Lauren MartinezAug 3, 2025
      Erratic mV output from your Speedline Technologies Industrial Equipment can be caused by a fault in the preamplifier or wiring. To resolve this, verify the preamplifier shield connections and ensure the cable shield wire is maintained through all cable splices.
  • A
    Amber RichardsonAug 8, 2025
    What to do if mV output stuck at zero on Speedline Technologies ELECTROVERT Aquastorm?
    • J
      Jimmy SmallAug 8, 2025
      If the mV output is stuck at zero on your Speedline Technologies Industrial Equipment, it could be due to a shorted input signal. Check the preamplifier cable connections and shielding.
  • C
    Carla MontoyaAug 13, 2025
    How to fix mV output stuck at 1.4 VDC on Speedline Technologies ELECTROVERT Aquastorm?
    • K
      Kristina WhiteAug 13, 2025
      If the mV output on your Speedline Technologies Industrial Equipment is stuck at 1.4 VDC, it indicates a faulty preamplifier. The suggested solution is to replace the preamplifier.
  • M
    Matthew SkinnerAug 17, 2025
    What causes mV output stuck at zero on Speedline Technologies ELECTROVERT Aquastorm?
    • N
      Natalie PerryAug 17, 2025
      If the mV output is stuck at zero on your Speedline Technologies Industrial Equipment, this can happen due to cracked electrode glass. In this case, replace the electrode.
  • M
    Melanie AllenAug 22, 2025
    What to do if mV output is erratic on Speedline Technologies Industrial Equipment?
    • C
      Craig NicholsonAug 22, 2025
      Erratic mV output from your Speedline Technologies Industrial Equipment can occur due to several reasons: * Poor contact between the electrode and preamplifier connectors: Check the contacts and ensure they are clean and dry. * Fouled or aged electrode: Clean the electrode. * Ground loop: Isolate the electrode in a test beaker. If the output stabilizes, ground loops may be the cause. Isolate instrument outputs.
  • N
    Nancy ChurchAug 28, 2025
    Why is mV output stuck at 1.4 VDC on Speedline Technologies ELECTROVERT Aquastorm Industrial Equipment?
    • D
      Dawn HigginsAug 28, 2025
      If the mV output on your Speedline Technologies Industrial Equipment remains stuck at 1.4 VDC, the preamplifier may be faulty. Replace it to resolve the issue.

Summary

Safety Information

Potential Hazards

Details potential hazards encountered during operation, including hot surfaces, electrical, mechanical, and breathing risks.

Lock-Out Tag-Out Procedures

Provides procedures for safely isolating energy sources before performing maintenance or upgrades.

Options and Technical Data

Electrical Specifications

Provides detailed electrical requirements for Aquastorm 90â„¢, 100â„¢, and 200â„¢ systems.

Password Protection

Information on installing and configuring the keyswitch password protection for access control.

Flow Meters

Discusses the installation, configuration, and maintenance of flow meters for water balance.

pH Monitor

Explains the function, installation, and maintenance of the pH monitor for water quality.

Detergent Injection

Details the automatic detergent injection system for cleaning processes.

Resistivity Meter

Covers the resistivity meter for monitoring water quality in the final rinse stage.

Hurricane Jet Nozzles and Pumps

Describes enhanced cleaning nozzles and associated pump upgrades for improved performance.

Rear Emergency Stops

Password Protection

Conveyor Enhancements

CheckMate Hold Down Conveyor

Describes the CheckMateâ„¢ hold down conveyor for securing product during cleaning.

Flow Meters

pH Monitor

Detergent Injection

Resistivity Monitor

Configuration

Steps for configuring the system software to recognize and operate the resistivity monitor.

Hurricane Jets and Pumps

Functional Description

Describes the Hurricane Jetâ„¢ nozzles and their function in enhancing PCB cleaning.

Dryer Add-On Modules

Dryer Modifications

CAT

Describes the Compressed Air Technology (CAT) option for enhanced drying.

Blower Enhancements

Blower Fail Detect

Explains the electronic monitor for blower operation and failure detection.

Sump Pump

Installation

Steps for installing the sump pump assembly and its plumbing and electrical connections.

Speedline Technologies ELECTROVERT Aquastorm Specifications

General IconGeneral
Wash TypeAqueous
ManufacturerSpeedline Technologies
ModelAquastorm
Wash StagesMultiple
Rinse StagesMultiple
Heater TypeElectric
ApplicationPCB assembly
Max PCB WidthVaries by model
Power SupplyVaries by region
DimensionsVaries by model
WeightVaries by model