Loading...
. . . . .
DETERGENT INJECTION
General Cleaning
2-9317-600-00-0 Aquastorm™ Series Options Guide 9-181
General Cleaning
Introduction The maintenance process is broken down into several procedures. Refer to the
specific procedure for details on the required maintenance. Visual inspection of
the saponifier unit should be part of the standard daily maintenance procedures.
Safety To ensure personal safety and avoid equipment damage observe the following:
CAUTION
If the detergent injector fails to operate properly or is damaged, ensure a qualified
plumber performs the check out procedure.
ATTENTION
If a replacement detergent injector assembly is required contact Electrovert
customer support.
Materials required Use the following materials for cleaning:
White, lint-free cloth
All purpose ammonia based cleaner
•Clean shop water
Procedure Perform the following routine maintenance
1. Clean the vinyl tubing and saponifier low level sensor using a white, lint free,
soft cloth and an all purpose ammonia based cleaner.
2. Clean detergent storage tank with clean water.
3. Inspect all electrical connections and lines for damage.
4. Inspect all plumbing connections for possible leaks.