FLOW METERS
Software Configuration
2-9317-600-00-0 Aquastorm™ Series Options Guide 7-137
Software Configuration
Introduction The Electrovert service person performing installation or the system administrator
should configure the machine.
After installing a flow meter, configure the system software to recognize it. The
configuration screens interface with the system software.
System software may lock up if the operator attempts to configure items that do
not exist on the system.
Diagram Displayed below is Configuration Screen #4:
Figure 7–3
Navigating the menu
screens
To access and navigate the configuration screens:
Press the Menu key on the LDC Interface key pad to access the main configu-
ration screen.
Scroll between the configuration screens by pressing the page up or page
down keys.
Move the underline screen cursor to a specific option by pressing the up or
down arrow keys. Press the Enter key to toggle between selection choices.
ALARM_PROCESS SET
WATCH_DOG TEST
PRE_WASH_FLOW YES
FINAL_RINSE_FLOW YES
FLOW_UNITS GPM
GAS_HEAT_WASH NO
GAS_HEAT_RINSE NO
MACH_LEN_PCT 50