EasyManua.ls Logo

Speedline Technologies ELECTROVERT Aquastorm - Electrical Specifications

Speedline Technologies ELECTROVERT Aquastorm
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
. . . . .
OPTIONS AND TECHNICAL DATA
Aquastorm 90™ Systems
2-9317-600-00-0 Aquastorm™ Series Options Guide 2-19
Section B:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications
Aquastorm 90™ Systems
Introduction Refer to the electrical specifications provided to ensure adequate power is
installed at the site where the system is installed.
Table The following table lists the power requirements for an Aquastorm 90™ system.
Specification Type Specification
Standard Electrical
Requirements
Normal operating power is
80-85% of maximum power
required, depending on process
parameters and operation load
for the product being run.
Standard voltage: 460 VAC, 3 phase, 60 Hz. (214 Max. FLA)
Other voltages: 380 VAC, 3 phase, 50 Hz. (259 Max. FLA)
Single point electrical drop:
Integrated system disconnect
Not available for 220 VAC systems
Lock out/Tag out capability
All loads configured with over current protection
Full Load Calculation FLA (Full Load Amps)
Total Machine kVA x 1000
Amps Required
=
(1.732) (Machine Voltage)
Aquastorm 90™ Modules
Module Total Power Module Total Power
Controls 3 kVA Add-On Dryer #2 (Opt.)
Wash Module 7.5 HP Blower (Std.) 7.7 kVA
Heaters (2 @ 16 kVA) 32.kVA 10 HP Blower (Opt.) 10 kVA
5 HP Pump (Std.) 5 kVA 15 HP Blower (Opt.) 14.6 kVA
10 HP Pump (Opt.) 10 kVA
15 HP Pump (Opt.) 14.6 kVA Drain Options
Dryer Module ¾ HP Sump Pump (Opt.) 0.83 kVA
7.5 HP Blower (Std.) 7.7 kVA 2 HP Sump Pump (Opt.) 2.2 kVA
10 HP Blower (Opt.) 10 kVA
15 HP Blower (Opt.) 14.6 kVA
Optional Electrical Connection
Integrated system disconnect
not available for 220 VAC.
Other voltage: 220 VAC, 3 phase, 60 Hz. (428 Max. FLA)
Electrical Codes/Compliance Underwriters Laboratory (UL)
Listed for factory automation on 440 V and 220 V machines
European Customers
CE Compliance Package
Electrical Standard for Industrial Machinery, NFPA 70