HURRICANE JETS™ AND PUMPS
Remove Lower Nozzle
11-216 Aquastorm™ Series Options Guide Rev. 1
11
Remove Lower Nozzle
Introduction The lower wash or rinse Hurricane Jet™ periodically becomes clogged with debris
such as solder balls, polypropylene or CPVC particles, silicone and other foreign
debris. Ensure the system is turned Off, and all preparation steps are complete.
See Stop System Operation on page 211.
Safety To avoid equipment damage observe the following:
ATTENTION
Ensure all white, Teflon® gaskets are in good condition. Replace if necessary. The
Hurricane Jet™ will not function properly without the gasket.
Photographs Figure 11–14 shows the rear plumbing assembly connections for the lower
Hurricane Jet nozzle assembly. Figure 11–15 shows the lower nozzle from the
front.
Figure 11–14
Figure 11–15
M5 Nut [Two (2) Places]
Manifold
Quick Clamp
Tank Lid
Lower Plumbin
g
Quick Clamps
Lower Conveyor
Upper Hurricane Jet™ Nozzle and Brack
e
Lower Hurricane Jet™ Nozzle
Return Rail