EasyManua.ls Logo

Speedline Technologies ELECTROVERT Aquastorm - Section C. Preventive Maintenance; Overview

Speedline Technologies ELECTROVERT Aquastorm
368 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REAR EMERGENCY STOPS
Overview
3-52 Aquastorm™ Series Options Guide Rev. 1
3
Section C:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preventive Maintenance
Overview
Introduction A strong preventive maintenance program is the best method to cut costs,
increase system reliability, and enhance productivity. The time used for cleaning,
inspecting, and servicing ensures consistent production quality and increases the
extended service life of the machine.
Safety To ensure personal safety and avoid equipment damage observe the following:
CAUTION
Qualified maintenance staff should perform the following cleaning steps. If any
damage to the plumbing, assembly, or nozzle is detected, contact Electrovert
Customer Service.
Electrical Hazard
If an E-Stop fails to operate properly or is damaged, ensure a qualified electrical
engineer performs the check out procedure.
Maintenance Schedule Refer to the following maintenance schedule to ensure proper machine and option
operation.
Materials required Use the following materials for cleaning:
White, lint-free cloth
All purpose ammonia based cleaner
Procedure Perform the following routine maintenance
1. Clean the E-Stops using a white, lint free, soft cloth and an all purpose ammo-
nia based cleaner.
2. Inspect E-Stops for damage.
Daily Maintenance — Every eight (8) hours of Operation
Cleaning Procedure Reference
Clean E-Stops

Table of Contents