DRYER MODIFICATIONS
Repair
15-298 Aquastorm™ Series Options Guide Rev. 1
15
Repair
Introduction In the unlikely event a radiant heater panel or thermocouple should fail to properly
heat, use the following information to replace the damaged heat panel or
thermocouple.
Safety To ensure personal safety and avoid equipment damage observe the following:
Hot Surface
Radiant heaters can reach temperatures up to 74 °C (165 °F). To avoid the
possibility of serious burns, allow the heaters to cool before performing repairs.
Never operate a radiant heater outside of the Aquastorm™ system cabinet.
Tools Required Use the following tools to access the radiant heater unit:
• Phillips screwdriver
• 10 mm wrench
• Channel lock pliers
Photograph Figure 15–18 shows the rear blower section and identifies the IR heater rear
access cover.
Figure 15–18
Shut Down/Start Up
Procedure
Use the following steps to prepare for the procedure.
1. Shut down Aquastorm™ system operation.
2. Ensure system power is Off.
3. Perform Lock Out/Tag Out steps. See Lock-Out Tag-Out on page 10.
4. Perform required procedure.
5. Remove Lock Out-Tag Out tags. See Lock-Out Tag-Out on page 10.
6. Begin system operation.
IR Heater
Access Door
Temperature
Probe
Thermocouple
Connecting Wire