DRYER MODIFICATIONS
Preventive Maintenance
2-9317-600-00-0 Aquastorm™ Series Options Guide 15-297
Procedure Perform the following steps to shut the system down and access the blower:
1. Shut down Aquastorm™ system operation.
2. Ensure system power is Off.
3. Open Dryer #2 or optional Dryer #4 window and remove the internal glass.
Set it aside in a safe place.
4. Allow the radiant panel unit to cool adequately to avoid the possibility of
burns.
5. Inspect the radiant heater unit for scale build up.
6. Use a lint free soft cloth dampened with a mild solution of descaler to wipe
down the unit and remove the scale build up.
7. Replace the internal glass cover in Dryer #2 or optional Dryer #4 and close
the dryer module window.
8. Begin system operation. For detailed information refer to the Aquastorm 100™
or Aquastorm 200™ Programming and Operations Guide.