DRYER ADD-ON MODULES
Installation Overview
14-260 Aquastorm™ Series Options Guide Rev. 1
14
Installation Overview
Introduction The sound enclosure and utility sink unit is welded on the exit end of the
machine. In a field installation, prior to installing a single or dual add-on dryer
module the field service representative must perform the following tasks:
• Disconnect and remove the optional CheckMate™ conveyor belt
• Disconnect and remove the standard conveyor belt
• Remove the exit end conveyor unit
• Remove front aluminum rail between access windows and front access doors
• Heat and remove polypropylene weldment
• Pry sound enclosure and utility sink unit from exit end of Aquastorm™ system
Safety To ensure personal safety and avoid equipment damage observe the following:
ATTENTION
A factory trained field service representative must disconnect and remove the
sound enclosure and sink unit.
ATTENTION
Water may be present in the plumbing lines. Be sure to have shop towels
available to wipe up possible spills.