CONVEYOR ENHANCEMENTS
Functional Description
6-102 Aquastorm™ Series Options Guide Rev. 1
6
Functional Description
Introduction The entrance end photocell provides an automatic standby mode for PCB
detection. The photo sensor and reflector mount on the entrance angle adjust
inlet conveyor.
Auto start photocell operation sequentially starts pumps, blowers, and final rinse
water as PCB assemblies pass by and are detected. When PCB assemblies exit
the system, based on a fixed time and distance, photocell operation stops the
pumps, blowers, and final rinse water. The conveyor remains in operation to
move new PCB assemblies into the system.
When ordering the CheckMate™ option, the photocell mounts on the top of the
CheckMate™ exit end conveyor and provides a board jam alert to shut down
operation if a PCB should become entangled in the CheckMate™ conveyor.
Photographs Figure 6–14 shows a close up view of the photocell reflector and emitter units.
Figure 6–14
Sensor UnitReflector Unit