DRYER ADD-ON MODULES
Maintenance Schedule
2-9317-600-00-0 Aquastorm™ Series Options Guide 14-269
Section E:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preventive Maintenance
Maintenance Schedule
Introduction A strong preventive maintenance program is the best method to cut costs,
increase system reliability, and enhance productivity. The time used for cleaning,
inspecting, and servicing ensures consistent production quality and increases the
extended service life of the machine.
Safety To ensure personal safety and avoid equipment damage observe the following:
CAUTION
Qualified maintenance staff should perform the following cleaning steps. If any
damage to the blowers, motors, air hoses, filter mounts, or plumbing is noted,
contact Electrovert Customer Service.
Maintenance Schedule Refer to the following maintenance schedule to ensure proper machine and option
operation.
Monthly Maintenance — Every 160 hours of Operation
Cleaning Procedure Reference
Inspect all blower belts
See Access Blower Motor Belt on page 321.
Inspect and clean or replace blower air filters
See Blower Air Filters on page 270.