DRYER MODIFICATIONS
Repair
2-9317-600-00-0 Aquastorm™ Series Options Guide 15-299
Procedure Use the following steps to replace a radiant heater unit:
7. Use a Phillips screwdriver to remove the four (4) screws holding the radiant
heater rear cover in place. Set the cover and screws aside in a safe place.
8. Turn the temperature probe counterclockwise to unscrew it from the radiant
heater rear cover.
1. Slide the upper or lower radiant heater unit out through the rear of the
machine.
2. Use a 10 mm wrench to disconnect the wires from the damaged unit and
connect them to the replacement unit.
3. If necessary, replace the radiant heater unit or thermocouple as discussed
below.
4. Slide the replacement radiant heater unit back into the machine.
5. Turn the temperature probe clockwise to screw the it back into the radiant
heater rear cover.
6. Use a Phillips screwdriver to replace the heater rear cover and four (4) self
tapping screws.
Photograph Figure 15–19 shows the upper IR panel and thermocouple probe.
Figure 15–19
Procedure Use the following steps to replace a thermocouple probe:
1. Grasp and turn the thermocouple probe one quarter turn counterclockwise to
loosen and remove it from the top of the radiant heater unit.
2. Disconnect the connecting wire from the thermocouple and connect the con-
necting wire to the replacement thermocouple.
3. Slide the thermocouple into the top of the radiant heater panel and turn it one
quarter turn clockwise to seat it into place.
4. Slide the upper radiant heater unit back into the machine.
Upper IR
Panel
Thermocouple
Probe