FLOW METERS
Software Configuration
7-138 Aquastorm™ Series Options Guide Rev. 1
7
Configuration
Procedure
Use the following steps to configure flow meter operation:
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key three times to display configuration screen #4.
3. Press the enter key to toggle to YES and indicate the pre-wash or final rinse
flow meter is installed.
4. Press the enter key to accept the configuration.
5. Press the enter key to accept the configuration.
6. Press the Menu key to accept the changes.
7. The update screen displays and the system returns to the main menu.
8. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 90™ and 100™ Operation Manual.