CONVEYOR ENHANCEMENTS
Auto Start Configuration
6-106 Aquastorm™ Series Options Guide Rev. 1
6
Configuration
Procedure
Configure the entrance end photocell as follows:
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key three (3) times to display configuration screen #4.
3. Press the enter key to toggle through the options for machine length percent-
age and enter the percentage of time the machine continues operation after
the last item exits the machine. Recommended percentage rate is 50%.
4. Press the enter key to accept the configuration.
5. Press the Menu key to accept the changes.
6. Result: The update screen displays and the system returns to the main menu.
7. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Programming and Operation Manual.