PH MONITOR
Overview
2-9317-600-00-0 Aquastorm™ Series Options Guide 8-159
Configuration
Procedure
Configure the Aquastorm™ software to recognize the pH monitor as follows
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the enter key to toggle to YES and indicate the pH monitor is installed.
3. Press the enter key to accept the configuration.
4. Press the Menu key to accept the changes.
5. Result: The update screen displays and the system returns to the main menu.
6. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Operation Manual.