RESISTIVITY MONITOR
Software Configuration
10-192 Aquastorm™ Series Options Guide Rev. 1
10
Procedure Configure the Aquastorm™ software to recognize the resistivity monitor as
follows
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key once to display configuration screen #2.
3. Press the enter key to toggle to YES and indicate the resistivity option is
installed.
4. Press the enter key to accept the configuration.
5. Press the Menu key to accept the changes.
6. Result: The update screen displays and the system returns to the main menu.
7. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Programming and Operation Manual.
Diagrams Figure 10–4 displays Configuration Screen #4. Figure 10–5 shows the alarm
process screen.
Figure 10–4
Figure 10–5
ALARM_PROCESS SET
WATCH_DOG TEST
PRE_WASH_FLOW YES
FINAL_RINSE_FLOW YES
FLOW_UNITS GPM
GAS_HEAT_WASH NO
GAS_HEAT_RINSE NO
MACH_LEN_PCT 50
ALARM BAND ACTION REALARM
CONV 1.0 FPM WARNING 05 MIN
WASH 10 F SHUTDOWN 05 MIN
CHEM 10 F IGNORE 05 MIN
RINSE 10 F SHUTDOWN 05 MIN
BLWR 10F WARNING 05 MIN
SAPON SHUTDOWN 05 MIN
BLWR_FAIL SHUTDOWN 05 MIN