HURRICANE JETS™ AND PUMPS
Software Configuration
11-206 Aquastorm™ Series Options Guide Rev. 1
11
Configuration
Procedure
Configure the Hurricane Jet™ nozzle as follows
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the arrow keys to highlight the wash pump.
3. Press the enter key to toggle to HURRICANE and indicate the wash Hurricane
Jet™ nozzle is installed.
4. Press the enter key to accept the configuration.
5. Press the Menu key to accept the changes.
6. Result: The update screen displays and the system returns to the main menu.
7. When installed, repeat the process for the rinse Hurricane Jet™ nozzle on
Aquastorm 200™ systems.
8. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Programming and Operation Manual.