HURRICANE JETS™ AND PUMPS
Nozzle Orifice Cleaning
2-9317-600-00-0 Aquastorm™ Series Options Guide 11-223
Procedure Use the following steps to clean the nozzle orifice:
1. Ensure the upper or lower nozzle has been removed for cleaning. See
Remove Single/Upper Nozzle on page 212. See Remove Lower Nozzle on
page 216.
2. Using a 0.020 feeler gauge, insert it into the orifice of the Hurricane Jet™ noz-
zle.
3. Slide the feeler gauge back and forth inside the orifice to dislodge any debris
which may be clogging the nozzle orifice.
4. At the rear of the machine, using clean, dry, compressed air, blow the air into
the end, and out through the orifice of the nozzle to remove any debris.
5. Repeat the cleaning steps as necessary to remove any additional debris.
6. After removing debris and cleaning the nozzle orifice, reinstall the nozzle and
resume system operation. See Reinstall Upper/Single Nozzle on page 214.
See Reinstall Lower Nozzle on page 219. See Resume System Operation on
page 224.