NATURAL GAS HEATING
Software Configuration
2-9317-600-00-0 Aquastorm™ Series Options Guide 12-235
Configuration
Procedure
Configure the gas heat option as follows
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key three (3) times to display configuration screen #4.
3. Press the arrow keys to highlight gas_heat_wash for any Aquastorm™ system.
4. Press the arrow keys to highlight gas_heat_rinse for an Aquastorm 200™ sys-
tem.
5. Press the enter key to toggle to yes and indicate the gas heat option is
installed.
6. Press the enter key to accept the configuration.
7. Press the Menu key to accept the changes.
8. Result: The update screen displays and the system returns to the main menu.
9. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Programming and Operation Manual.