SUMP PUMP
Software Configuration
17-336 Aquastorm™ Series Options Guide Rev. 1
17
Configuration
Procedure
Configure the Aquastorm™ software to recognize the sump pump as follows:
1. Press the menu key on the LCD interface keypad to access configuration
screen #1.
2. Press the page down key once to display configuration screen #2.
3. Press the enter key to toggle to Standard and indicate a single sump unit is
installed.
OR
Toggle to Recycle to indicate a sump unit connected to a recycling system is
installed.
4. Press the enter key to accept the configuration.
5. Press the enter key to toggle to Standard to indicate that dual sump units are
installed and the second unit is operational.
6. Press the enter key to accept the configuration.
7. Press the Menu key to accept the changes.
8. Result: The update screen displays and the system returns to the main menu.
9. Begin system operation. For detailed information refer to the Aquastorm 200™
or Aquastorm 100™ Programming and Operation Manual.