24-Port 10/100Mbps Layer 2 Switch w/ 4 Gigabit Ports and 2 Shared Mini-GBIC Slots
12-2
system contact
To enter identification information of a contact person.
Command
system contact <contact info>
Syntax Description
contact info
A maximum of 50 characters is allowed. A NULL string is not
accepted.
Default Settings
SysContact
Command Modes
Global Configuration Mode
User Guidelines
Use this command to provide the name and/or other information to identify a
contact person who is responsible for the Switch.
Example
switch(config)# system contact TechSupport
Command History
Version
History
1.00.001
This command was introduced.
system location
To enter a description of the location of the Switch.
Command
system location <location info>
Syntax Description
location info
A maximum of 50 characters is allowed. A NULL string is not
accepted.
Default Settings
SysLocation
Command Modes
Global Configuration Mode
User Guidelines
This command enters a description of the location of the Switch.
Example
switch(config)# system location 5F east
Command History
Version
History
1.00.001
This command was introduced.
system web-timeout
To define the amount of time the device times out when no user activity occurs on
the web interface.