EasyManua.ls Logo

TRENDnet TL2-E284 - System Cli-Timeout; Default Ip Address

TRENDnet TL2-E284
293 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24-Port 10/100Mbps Layer 2 Switch w/ 4 Gigabit Ports and 2 Shared Mini-GBIC Slots
12-3
Command
system web-timeout <180-3600 seconds>
Syntax Description
180-3600 seconds
The web interface logs out the current user when no user
activity input for 180-3600 seconds.
Default Settings
600 seconds
Command Modes
Global Configuration Mode
User Guidelines
This command defines the amount of time the device times out when no user
activity occurs on the web interface.
Example
switch(config)# system web-timeout 3600
Command History
Version
History
1.00.001
This command was introduced.
system cli-timeout
To define the amount of time the device times out when no user activity occurs on
the CLI interface.
Command
system cli-timeout <1-18000 seconds>
Syntax Description
1-18000 seconds
The cli interface logs out the current user when no user
activity input for 1-18000 seconds.
Default Settings
1800 seconds
Command Modes
Global Configuration Mode
User Guidelines
This command defines the amount of time the device times out when no user
activity occurs on the web interface.
Example
switch(config)# system cli-timeout 18000
Command History
Version
History
1.00.001
This command was introduced.