Item Description
External Dimensions
66.5
302 71
67 4
28
CN53: ZHR-8
J.S.T. Mfg. Co., Ltd.
CN3: HDR-EC14LFDTN-SLE-PLUS
Honda Tsushin Kogyo Co., Ltd.
Approx. mass: 0.08 kg
Unit: mm
Refer to the following manual for the operating procedures for the Digital Operator.
& Σ-7-Series Servo Drive Digital Operator Operating Manual (Manual No.: SIEP
S800001 33)
5.9.2 Computer Connector (CN7)
To use the SigmaWin+ Engineering Tool, connect the computer on which the SigmaWin+
is installed to CN7 on the SERVOPACK.
Refer to the following manual for the operating procedures for the SigmaWin+.
& AC Servo Drive Engineering Tool SigmaWin+ Operation Manual (Manual No.: SIET
S800001 34)
Use the YASKAWA-specified cables. Operation will not be dependable
due to low noise resistance with any other cable.
Refer to the catalog for details on the Computer Cable.
5.9.3 Analog Monitor Connector (CN5)
To use an analog monitor, connect CN5 on the SERVOPACK.
n Wiring Example
Measuring probe
Measuring
instrument*
Measuring probe
White
Red
Black
Black
Probe ground
Probe ground
White
Red
Black
Connect to CN5
on the SERVOPACK.
Black
Fig. 86: Analog Monitor Connector (CN5) - Wiring Example
Sigma-7 Series SERVOPACKs
Wiring and Connecting SERVOPACKs
Connecting the Other Connectors > Analog Monitor Connector (CN5)