Code Data Type Coding
(decimal)
Range
UDINT Unsigned 32-bit integer 7 0 to 4,294,967,295
FP Floating Point 8
VS Visible String 9
OS Octet String 10
N2 Normalised value 16 bit 113
N4 Normalised value 32 bit 114
2.3.3 Data Ranges
The following table lists the data units and notations that are used in this manual.
Notation Description
Pos. unit The user-defined position reference unit that is set in position user unit
(2301h).
1 [Pos. unit] = 2301h|00 / 2301h|01 [inc]
Vel. unit The user-defined speed reference unit that is set in velocity user unit
(2302h).
1 [Vel. unit] = 2302h|00 / 2302h|01 [inc/ms]
Acc. unit The user-defined acceleration reference unit that is set in acceleration
user unit (2303h).
1 [Acc. unit] = 2303h|00 / 2303h|01 x 10
4
[inc/s
2
]
inc This is the encoder pulse unit.
For a 24-bit encoder, the resolution is 16,777,216 [inc] per rotation.
2.4 Interpreting the Nameplate
The following basic information is provided on the nameplate.
Order number
Serial number
BTO information
Degree of protection
Surrounding air temperature
SERVOPACK model
Fig. 8: Nameplate SGD7S-1R6A
Sigma-7 Series SERVOPACKs
Basic Information on SERVOPACKs
Interpreting the Nameplate
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 43