5.4.3 Wiring Procedure for Main Circuit Connector
Required Item Remarks
Spring Opener or Flat-
blade Screwdriver
n Spring Opener
SERVOPACK accessory
(You can also use model 1981045-1 from Tyco Elec-
tronics Japan G.K.)
n Flat-blade screwdriver
Commercially available screwdriver with tip width of 3.0
mm to 3.5 mm
1. Remove the main circuit connector and motor connector from the SERVOPACK.
Servomotor connector
Main circuit
connector
Enlarged View
Locks
2. Press in on the
locks to remove
the connectors.
1. Press in on
the lock.
Fig. 48: Removing the main circuit connector and motor connector from the SERVOPACK
2. Remove the sheath from the wire to connect.
8 mm to 9 mm
Fig. 49: Removing the sheath from the wire
3. Open the wire insertion hole on the terminal connector with the tool. There are the
following two ways to open the insertion hole. Use either method.
Using a Spring Opener Using a Flat-blade Screwdriver
Open the insertion hole with the Spring
Opener as shown in the figure.
Wire
Spring Opener
Firmly insert a flat-blade screwdriver
into the screwdriver insertion hole to
open the wire insertion hole.
Required Items
Sigma-7 Series SERVOPACKs
Wiring and Connecting SERVOPACKs
Wiring the Power Supply to the SERVOPACK > Wiring Procedure for Main Circuit Connector