Reverse Force Limit
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn484 0 to 800 1%* 30 Immediately Setup
(applies to Speed Control, Position Control and Force Control)
* Set a percentage of the rated motor force.
If the setting of Pn483 or Pn484 is too low, the force may be insufficient
for acceleration or deceleration of the Servomotor.
t
Pn484
Pn483
t
Without Internal Force Limits
(Output to the maximum force is possible.)
Speed
With Internal Force Limits
Maximum force
Speed
Force limit
Fig. 166: Internal Force Limits - Linear Servomotors
7.8.3 External Torque Limits
You can limit the torque only when required by the operating conditions of the machine by
turning a signal ON and OFF.
You can use this for applications such as stopping on physical contact, or holding a work-
piece with a robot.
The /P-CL (Forward External Torque Limit) and /N-CL (Reverse External Torque Limit)
signals are used as the external torque limit reference signals. The /P-CL signal is used
for the forward torque limit and the /N-CL signal is used for the reverse torque limit.
External Torque Limit Ref-
erence Signals
Sigma-7 Series SERVOPACKs
Application Functions
Selecting Torque Limits > External Torque Limits
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 223