3. Click the Monitor Mode Button.
Fig. 325: Wiring Check AXIS#00
1 Input signal status
2 Output signal status
ð
You can also use the above window to check wiring.
– Checking Input Signal Wiring
Change the signal status at the host controller. If the input
signal status on the window changes accordingly, then the
wiring is correct.
– Checking Output Signal Wiring
Click the Force Output Mode Button. This will force the
output signal status to change. If the signal status at the
host controller changes accordingly, then the wiring is cor-
rect. You cannot use the Force Output Mode Button while
the servo is ON.
10.4 Monitoring Machine Operation Status and Signal Waveforms
10.4.1 Overview
To monitor waveforms, use the SigmaWin+ trace function or a measuring instrument,
such as a memory recorder.
10.4.2 Items That You Can Monitor
You can use the SigmaWin+ or a measuring instrument to monitor the shaded items in
the following block diagram.
Sigma-7 Series SERVOPACKs
Monitoring
Monitoring Machine Operation Status and Signal Waveforms > Items That You Can Monitor
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 438