Soft Start Deceleration Time
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn306 0 to 10,000 1 ms 0 Immediately Setup
(applies to Speed Control)
Jogging Speed
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn383 0 to 10,000 1 mm/s 50 Immediately Setup
(applies to Speed Control, Position Control and Torque Control)
Soft Start Acceleration Time
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn305 0 to 10,000 1 ms 0 Immediately Setup
(applies to Speed Control)
Soft Start Deceleration Time
Setting
Range
Setting Unit Default Set-
ting
When Ena-
bled
Classifica-
tion
Pn306 0 to 10,000 1 ms 0 Immediately Setup
(applies to Speed Control)
8.4.3 Applicable Tools
The following table lists the tools that you can use to perform jogging and the applicable
tool functions.
Tool Function Operating Procedure Reference
Digital Operator Fn002
& Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001 33)
SigmaWin+ Test Run - Jog
Ä
Chap. 8.4.4 ‘Operating Procedure’
page 269
8.4.4 Operating Procedure
Use the following procedure to jog the motor.
Linear Servomotors
Sigma-7 Series SERVOPACKs
Trial Operation and Actual Operation
Trial Operation for the Servomotor without a Load > Operating Procedure
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 269