Red LED (BF) State Description
Off No error The device is ready to communicate
On Error Communication error occurs, Run mode cyclic
communication has been interrupted and no
connection established.
The Link/Activity indicators show whether Communications Cables are connected to the
CN6A and CN6B connectors and whether communications are active.
Green LED
state
Link Activity
On Yes A Communications Cable is connected, but
data communications are not being performed.
Flickering Yes Data communications are in progress.
Off No A Communications Cable is not connected and
the PROFINET controller is not running.
18.3 Corresponding SERVOPACK and SigmaWin+ Function Names
18.3.1 Overview
This section gives the names and numbers of the utility functions and monitor display
functions used by the SERVOPACKs and the names used by the SigmaWin+.
18.3.2 Corresponding SERVOPACK Utility Function Names
SigmaWin+ SERVOPACK
Menu
Dialog
Box
Button
Function Name Fn No. Function Name
Setup Origin Search Fn003 Origin Search
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Adjust the Analog Monitor
Output
Fn00C Adjust Analog Monitor Output
Offset
Fn00D Adjust Analog Monitor Output
Gain
Adjust the Motor Current
Detection Signal Offsets
Fn00E Autotune Motor Current Detection
Signal Offset
Fn00F Manually Adjust Motor Current
Detection Signal Offset
Red LED (BF) states
Green LED Link/Activity
status
Sigma-7 Series SERVOPACKs
Appendices
Corresponding SERVOPACK and SigmaWin+ Function Names > Corresponding SERVOPACK Utility Function Names
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 761