5. Click the Forward Button or the Reverse Button.
An origin search will be performed only while you hold down the mouse button. The
motor will stop when the origin search has been completed.
Fig. 216: Origin Search - Forward - Reverse
This concludes the origin search procedure.
8.7.4 Test without a Motor
A test without a motor is used to check the operation of the host controller and peripheral
devices by simulating the operation of the Servomotor in the SERVOPACK, i.e., without
actually operating a Servomotor. This test allows you to check wiring, debug the system,
and verify parameters to shorten the time required for setup work and to prevent damage
to the machine that may result from possible malfunctions. The operation of the Servo-
motor can be checked with this test regardless of whether the Servomotor is actually con-
nected or not.
Host controller
Reference
SERVOPACK
Reference
Response
Simulates operation
without a motor.
Response
Fig. 217: Test without a Motor
Sigma-7 Series SERVOPACKs
Trial Operation and Actual Operation
Convenient Function to Use during Trial Operation > Test without a Motor