4. While watching the analog monitor, use the +1 and -1 Buttons to adjust the offset.
There are two channels: CH1 and CH2. If necessary, click the down arrow on the
Channel Box and select the channel.
Fig. 332: Adjust the Analog Monitor Output AXIS#00 - Analog Monitor Output Offset
This concludes adjusting the analog monitor output.
10.5 Monitoring Product Life
10.5.1 Items That You Can Monitor
Monitor Item Description
SERVOPACK Installation Environment The operating status of the SERVOPACK in terms of the installation
environment is displayed. Implement one or more of the following
actions if the monitor value exceeds 100%.
n Lower the surrounding temperature.
n Decrease the load.
Servomotor Installation Environment The operating status of the SERVOPACK in terms of the installation
environment is displayed. Implement one or more of the following
actions if the monitor value exceeds 100%.
n Lower the surrounding temperature.
n Decrease the load.