3 Selecting a SERVOPACK
3.1 Overview
This chapter provides information required to select SERVOPACKs, such as specifica-
tions, block diagrams, dimensional drawings, and connection examples.
3.2 Ratings and Specifications
3.2.1 Ratings
This section gives the ratings and specifications of SERVOPACKs.
Model SGD7S- R70A R90A 1R6A 2R8A 5R5A
Maximum Applicable Motor Capacity [kW] 0.05 0.1 0.2 0.4 0.75
Continuous Output Current [Arms] 0.66 0.91 1.6 2.8 5.5
Instantaneous Maximum Output Current [Arms] 2.1 3.2 5.9 9.3 16.9
Main Circuit Power Supply 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]* 0.4 0.8 1.3 2.5 4.1
Control Power Supply 200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]* 0.2 0.2 0.2 0.2 0.2
Power Supply Capacity [kVA]* 0.2 0.3 0.5 1.0 1.6
Power Loss* Main Circuit Power Loss [W] 5.0 7.0 11.9 22.5 38.9
Control Circuit Power Loss [W] 12 12 12 12 14
Built-in Regenerative Resistor
Power Loss [W]
− − − − 8
Total Power Loss [W] 17.0 19.0 23.9 34.5 60.9
Regenerative
Resistor
Built-In Regen-
erative Resistor
Resistance [Ω] − − − − 40
Capacity [W] − − − − 40
Minimum Allowable External
Resistance [Ω]
40 40 40 40 40
Overvoltage Category III
* This is the net value at the rated load.
Three-Phase, 200 VAC
Sigma-7 Series SERVOPACKs
Selecting a SERVOPACK
Ratings and Specifications > Ratings
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 58