Parameter Forward/
Reverse Refer-
ence
Motor Direction and Encoder Divided Pulse
Outputs
Applicable
Overtravel
Signal (OT)
Reverse refer-
ence
Torque reference
Time
Motor speed
CCW
+
Phase-A lead
Encoder Divided Pulse Outputs
PAO
PBO
N-OT (Reverse
Drive Prohibit)
signal
The trace waveforms of the SigmaWin+ are shown in the above table for
the torque reference and motor speed diagrams. If you measure them on
a measuring instrument, e.g., with an analog monitor, the polarity will be
reversed.
Before you set this parameter, make sure that Pn080 = n.X (Motor Phase
Sequence Selection) is set correctly.
Parameter Forward/
Reverse Refer-
ence
Motor Moving Direction and Encoder
Divided Pulse Outputs
Applicable
Overtravel
Signal (OT)
Pn000
n.0 Use
the direction in
which the linear
encoder counts
up as the for-
ward direction.
(default setting)
Forward refer-
ence
Force reference
Motor speed
Time
Moves in the
count-up
direction.
+
Encoder Divided Pulse Outputs
Phase-B lead
PAO
PBO
P-OT (Forward
Drive Prohibit)
signal
Reverse refer-
ence
Moves in the
count-down
direction.
Force reference
Motor speed
Time
+
Encoder Divided Pulse Outputs
Phase-A lead
PAO
PBO
N-OT (Reverse
Drive Prohibit)
signal
n.1 Use
the direction in
which the linear
encoder counts
down as the for-
ward direction.
Forward refer-
ence
Force reference
Motor speed
Time
Moves in the
count-down
direction.
+
Encoder Divided Pulse Outputs
Phase-B lead
PAO
PBO
P-OT (Forward
Drive Prohibit)
signal
Reverse refer-
ence
Moves in the
count-up
direction.
Force reference
Time
Motor speed
+
Encoder Divided Pulse Outputs
Phase-A lead
PAO
PBO
N-OT (Reverse
Drive Prohibit)
signal
The trace waveforms of the SigmaWin+ are shown in the above table for
the force reference and motor speed diagrams. If you measure them on a
measuring instrument, e.g., with an analog monitor, the polarity will be
reversed.
6.6 Setting the Linear Encoder Pitch
If you connect a linear encoder to the SERVOPACK through a Serial Converter Unit, you
must set the scale pitch of the linear encoder in Pn282.
If a Serial Converter Unit is not connected, you do not need to set Pn282.
Linear Servomotors
Sigma-7 Series SERVOPACKs
Basic Functions That Require Setting before Operation
Setting the Linear Encoder Pitch
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 146