17.4 PROFINET Parameter Request Error Codes
The following table shows the PROFIdrive parameter request error codes.
Error Meaning Used at
00h Impermissible
parameter number
Access to unavailable parameter
01h Parameter value
cannot be changed
Change access to a parameter value that cannot be
changed
02h Low or high limit
exceeded
Change access with value outside the limits
03h Invalid subindex Access to unavailable subindex
04h No array Access with subindex to non-indexed parameter
05h Incorrect data type Change access with value that does not match the
data type of the parameter
06h Setting not per-
mitted (can only be
reset)
Change access with value unequal to 0 when this is
not permitted
07h Description element
cannot be changed
Change access to a description element that cannot
be changed
09h No description data
available
Access to unavailable description (parameter value
is available)
0Bh No operation priority Change access rights without rights to change
parameters
0Fh No text array avail-
able
Access to text array that is not available (parameter
value is available)
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
PROFINET Parameter Request Error Codes