Not lit. Not lit. Not lit.Not lit.
Status Display
Fig. 389: Hard Wire Base Block Active Display
18.2.5 Overtravel Display
If overtravel has occurred, the display will change in the following order.
ƒ• ‚
Forward Overtravel (P-OT)
Status Display
Reverse Overtravel (N-OT)
Status Display
Status Display
Forward and Reverse Overtravel
Fig. 390: Overtravel Display
18.2.6 Forced Stop Display
During a forced stop, the following display will appear.
Status
Display
Not lit. Not lit. Not lit.Not lit. Not lit.
Fig. 391: Forced Stop Display
18.2.7 PROFINET Communications Indicators
Green LED
(RUN)
State Flash rates
LED off There is no connection to the
IO-Controller.
Never lit.
LED on Connection established with
IO-Controller and in RUN
mode.
Always lit.
LED blinking Connection established with
IO-Controller and in STOP
mode.
Equal on and off times with a fre-
quency of approximately 2,5 Hz: on
for approximately 200 ms followed by
off for approximately 200 ms.
LED Flash
Once
DCP Flash signal Flash Once means to flash the LED
with a duration of 3 sec with a fre-
quency of 1 Hz (500 ms on, 500 ms
off).
Green LED (RUN) states
Sigma-7 Series SERVOPACKs
Appendices
Interpreting Panel Displays > PROFINET Communications Indicators