DC Power Supply Input
Terminal Sym-
bols
Terminal Name Specifications and Reference
L1C, L2C Control power supply
terminals
AC power supply
Single-phase, 200 VAC to 240 VAC, -15%
to +10%, 50 Hz/60 Hz
DC power supply
L1C: 270 VDC to 324 VDC, -15% to +10%,
L2C: 0 VDC or
L2C: 270 VDC to 324 VDC, -15% to +10%,
L1C: 0 VDC
B1/
Main circuit power
supply input terminals for
DC power supply input
270 VDC to 324 VDC, -15% to +10%
2
0 VDC
L1, L2, L3, B2,
B3, 1,
− None. (Do not connect anything to these
terminals.)
If you use a DC power supply input to the SERVOPACK, make sure to set parameter
Pn001 to n.1 (DC power supply input supported) before inputting the power supply.
Refer to the following section for details.
Ä
Chap. 6.3.2 ‘AC Power Supply Input/DC Power Supply Input Setting’ page 143
Single-Phase, 100-VAC Power Supply Input
Terminal Sym-
bols
Terminal Name Specifications and Reference
L1 and L2 Main circuit power
supply input terminals for
AC power supply input
Single-phase, 100 VAC to 120 VAC, -15%
to +10%, 50 Hz/60 Hz
L1C and L2C Control power supply
terminals
Single-phase, 100 VAC to 120 VAC, -15%
to +10%, 50 Hz/60 Hz
B1 and B2 Regenerative Resistor
terminals
Ä
Chap. 5.4.6 ‘Wiring Regenerative Resis-
tors’ page 103
If the regenerative capacity is insufficient,
connect an External Regenerative Resistor
between B1/ and B2. Obtain an External
Regenerative Resistor separately.
You can use a single-phase, 100-VAC power supply input with the following models.
n SGD7S-R70F, -R90F, -2R1F, -2R8F