Parameter Meaning When Enabled Classification
Pn460
n.0
Do not adjust the first
stage notch filter auto-
matically during execu-
tion of autotuning without
a host reference, auto-
tuning with a host refer-
ence, and custom
tuning.
Immediately Tuning
n.1
(default
setting)
Adjust the first stage
notch filter automatically
during execution of auto-
tuning without a host ref-
erence, autotuning with
a host reference, and
custom tuning.
n.0
Do not adjust the second
stage notch filter auto-
matically when the
tuning-less function is
enabled or during execu-
tion of autotuning without
a host reference, auto-
tuning with a host refer-
ence, and custom
tuning.
n.1
(default
setting)
Adjust the second stage
notch filter automatically
when the tuning-less
function is enabled or
during execution of auto-
tuning without a host ref-
erence, autotuning with
a host reference, and
custom tuning.
This function reduces low vibration frequencies, for which the notch filters cannot be
used.
Normally, set Pn160 to n.1 (Adjust automatically) (default setting).
Vibration will be detected during autotuning without a host reference and anti-resonance
control will be automatically adjusted.
Anti-Resonance Control
Adjustment
Sigma-7 Series SERVOPACKs
Tuning
Autotuning without Host Reference > Automatically Adjusted Function Settings
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 335