Index
(hex)
Sub
Pn No.
Name
Access
PDO Mapping
Default value
Units
Type
6063h 0 B22 Position Actual Internal
Value
RO TPZD - Inc DINT
6064h 0 B24 Position Actual Value RO TPZD - Pos. units DINT
607Fh 0 B4C Max. Profile Velocity RW No Max. motor
speed
Vel. units UDINT
6083h 0 B50 Profile Acceleration RW RPZD 0 Acc. units UDINT
6084h 0 B52 Profile Deceleration RW RPZD 0 Acc. units UDINT
6085h 0 B54 Quick Stop Deceleration RW RPZD Max. motor
acceleration
Acc. units UDINT
60C5h 0 B7C Max. Acceleration RW No Max. motor
acceleration
Acc. units UDINT
60C6h 0 B7E Max. Deceleration RW No Max. motor
acceleration
Acc. units UDINT
605Ah 0 B13 Quick Stop Option Code RW No 2 (Slow
down on
quick stop
ramp)
- INT
605Dh 0 B16 Halt Option Code RW No 3 (Slow
down on
Max. Decel-
eration
(60C6h))
- INT
606Bh 0 B2E Velocity Demand Value RO TPZD 0 Vel. units DINT
606Dh 0 B32 Velocity Window RW No 0 Vel. units UINT
606Eh 0 B34 Velocity Window Time RW No 0 ms UINT
606Fh 0 B35 Velocity Threshold RW No 0 Vel. units UINT
60F4h 0 B84 Following Error Actual
Value
RO TPZD 0 Pos. units DINT
Sigma-7 Series SERVOPACKs
PROFIdrive Drive Profile
PROFIdrive Velocity Mode