Alarm Code Alarm Name Possible Cause Confirmation Correction Reference
A.Eb1
(1Eb1h)
Safety Function
Signal Input
Timing Error
The delay between
activation of the /
HWBB1 and /HWBB2
input signals for the
HWBB was ten
second or longer.
Measure the time
delay between the /
HWBB1 and /
HWBB2 signals.
The output signal cir-
cuits or devices for /
HWBB1 and /
HWBB2 or the SER-
VOPACK input signal
circuits may be
faulty. Alternatively,
the input signal
cables may be dis-
connected. Check to
see if any of these
items are faulty or
have been discon-
nected.
A failure occurred in
the SERVOPACK.
Replace the SERVO-
PACK.
A.EC8
(1EC8h)
Gate Drive Error
1 (An error
occurred in the
gate drive cir-
cuit.)
A failure occurred in
the SERVOPACK.
Turn the power
supply to the SER-
VOPACK OFF and
ON again. If an
alarm still occurs, the
SERVOPACK may
be faulty. Replace
the SERVOPACK.
A.EC9
(1EC9h)
Gate Drive Error
2 (An error
occurred in the
gate drive cir-
cuit.)
A.Ed1
(1Ed1h)
Command Exe-
cution Timeout
A timeout error
occurred for a
PROFINET command.
Check the motor
status when the
command is exe-
cuted.
Execute the Servo
ON command
(Enable Operation
command) only
when the motor is
not operating.
A.F10
(1F10h)
Power Supply
Line Open
Phase (The
voltage was low
for more than
one second for
phase R, S, or T
when the main
power supply
was ON.)
The three-phase
power supply wiring is
not correct.
Check the power
supply wiring.
Make sure that the
power supply is cor-
rectly wired.
Ä
Chap. 5.4
‘Wiring the
Power Supply to
the SERVO-
PACK’ page 92
The three-phase
power supply is unbal-
anced.
Measure the voltage
for each phase of the
three-phase power
supply.
Balance the power
supply by changing
phases.
A single-phase power
supply was input
without specifying a
single- phase AC
power supply input
(Pn00B = n.1).
Check the power
supply and the
parameter setting.
Match the parameter
setting to the power
supply.
Ä
Chap. 5.4
‘Wiring the
Power Supply to
the SERVO-
PACK’ page 92
A failure occurred in
the SERVOPACK.
Turn the power
supply to the SER-
VOPACK OFF and
ON again. If the
alarm still occurs, the
SERVOPACK may
be faulty. Replace
the SERVOPACK.