NoteAction
xx1200000950
Inspect the oil level.6
Required oil level: 58 mm ± 5 mm below
the sealing surface of the oil plug.
xx1300000692
Remove the oil dispenser and refit the
protective cap to the nipple.
7
Tightening torque: 24 NmRefit the vent hole plug.8
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section DANGER
- First test run may cause injury or damage!
on page 44.
9
142 3HAC044266-001 Revision: -
© Copyright 2013 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing oil, axis-1 gearbox
Continued