Physical Status
Alarm/Error
Status
Capture/Monitor
Status
Select the port role from Master or Slave.
Timing setting will be changed to "Received" if setting to Slave.
Protocol
If CPRI Link is set to Disabled, select the CPRI Protocol version from 1 or 2.
Protocol version 2 appears if the line rate is set to 4915.2 Mbps or more.
HDLC
Touch the drop-down menu to specify the Rate of slow C&M Channel.
Options depend on the line rate.
Ethernet
Select the check box if setting fast C&M Channel.
Touch the field to specify the Pointer. To set maximum Ethernet bit rate, set
"20" to the pointer. Actual Ethernet bit rate is proportional to the line rate
excluding 10137.6 Mbps.
8.1.3 Status Information
This section describes the status information available in the status area of
the CPRI/OBSAI ports setup screen.
8.1.3.1 Status Summary
The status summary displayed for the CPRI/OBSAI interface consists of the
following information:
The topmost part of the status area gives you access to information about
the current physical status of the selected interface. A summary consisting
of the most relevant status indicators is displayed constantly. By touching
the summary, you can open the dialog box where you can view the detailed
status information.
The middle part of the status area gives you access to alarm and error
information for the selected interface. The current status is indicated by the
lamp color.
A summary consisting of the most relevant alarm/error indications is
displayed constantly. By touching the summary, you can open the dialog
box where you can view all alarms/errors.
At the bottom of the status area, a button that gives you access to the
monitor information By touching the button, you can launch the Transceiver
information display.
8.1.3.2 Physical Details
Touching the topmost summary box in the status area of the Ports Setup
screen launches the dialog shown below.